Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.495
Filtrar
1.
Sci Rep ; 14(1): 8181, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589483

RESUMO

Temporal envelope modulations (TEMs) are one of the most important features that cochlear implant (CI) users rely on to understand speech. Electroencephalographic assessment of TEM encoding could help clinicians to predict speech recognition more objectively, even in patients unable to provide active feedback. The acoustic change complex (ACC) and the auditory steady-state response (ASSR) evoked by low-frequency amplitude-modulated pulse trains can be used to assess TEM encoding with electrical stimulation of individual CI electrodes. In this study, we focused on amplitude modulation detection (AMD) and amplitude modulation frequency discrimination (AMFD) with stimulation of a basal versus an apical electrode. In twelve adult CI users, we (a) assessed behavioral AMFD thresholds and (b) recorded cortical auditory evoked potentials (CAEPs), AMD-ACC, AMFD-ACC, and ASSR in a combined 3-stimulus paradigm. We found that the electrophysiological responses were significantly higher for apical than for basal stimulation. Peak amplitudes of AMFD-ACC were small and (therefore) did not correlate with speech-in-noise recognition. We found significant correlations between speech-in-noise recognition and (a) behavioral AMFD thresholds and (b) AMD-ACC peak amplitudes. AMD and AMFD hold potential to develop a clinically applicable tool for assessing TEM encoding to predict speech recognition in CI users.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Psicoacústica , Percepção da Fala/fisiologia , Fala , Estimulação Acústica , Potenciais Evocados Auditivos/fisiologia
2.
J Acoust Soc Am ; 155(4): 2724-2727, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38656337

RESUMO

The auditory sensitivity of a small songbird, the red-cheeked cordon bleu, was measured using the standard methods of animal psychophysics. Hearing in cordon bleus is similar to other small passerines with best hearing in the frequency region from 2 to 4 kHz and sensitivity declining at the rate of about 10 dB/octave below 2 kHz and about 35 dB/octave as frequency increases from 4 to 9 kHz. While critical ratios are similar to other songbirds, the long-term average power spectrum of cordon bleu song falls above the frequency of best hearing in this species.


Assuntos
Estimulação Acústica , Limiar Auditivo , Audição , Aves Canoras , Vocalização Animal , Animais , Vocalização Animal/fisiologia , Audição/fisiologia , Aves Canoras/fisiologia , Masculino , Psicoacústica , Espectrografia do Som , Feminino
3.
Hear Res ; 445: 108992, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38492447

RESUMO

Noise sensitivity and hyperacusis are decreased sound tolerance conditions that are not well delineated or defined. This paper presents the correlations and distributions of the Noise Sensitivity Scale (NSS) and the Hyperacusis Questionnaire (HQ) scores in two distinct large samples. In Study 1, a community-based sample of young healthy adults (n = 103) exhibited a strong correlation (r = 0.74) between the two questionnaires. The mean NSS and HQ scores were 54.4 ± 16.9 and 12.5 ± 7.5, respectively. NSS scores displayed a normal distribution, whereas HQ scores showed a slight positive skew. In Study 2, a clinical sample of Veterans with or without clinical comorbidities (n = 95) showed a moderate correlation (r = 0.58) between the two questionnaires. The mean scores were 66.6 ± 15.6 and 15.3 ± 7.3 on the NSS and HQ, respectively. Both questionnaires' scores followed a normal distribution. In both samples, participants who self-identified as having decreased sound tolerance scored higher on both questionnaires. These findings provide reference data from two diverse sample groups. The moderate to strong correlations observed in both studies suggest a significant overlap between noise sensitivity and hyperacusis. The results underscore that NSS and HQ should not be used interchangeably, as they aim to measure distinct constructs, however to what extent they actually do remains to be determined. Further investigation should distinguish between these conditions through a comprehensive psychometric analysis of the questionnaires and a thorough exploration of psychoacoustic, neurological, and physiological differences that set them apart.


Assuntos
Hiperacusia , Zumbido , Adulto , Humanos , Hiperacusia/diagnóstico , Inquéritos e Questionários , Som , Psicoacústica
4.
J Acoust Soc Am ; 155(2): 901-914, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38310608

RESUMO

Dealing with newborns' health is a delicate matter since they cannot express needs, and crying does not reflect their condition. Although newborn cries have been studied for various purposes, there is no prior research on distinguishing a certain pathology from other pathologies so far. Here, an unsophisticated framework is proposed for the study of septic newborns amid a collective of other pathologies. The cry was analyzed with music inspired and speech processing inspired features. Furthermore, neighborhood component analysis (NCA) feature selection was employed with two goals: (i) Exploring how the elements of each feature set contributed to classification outcome; (ii) investigating to what extent the feature space could be compacted. The attained results showed success of both experiments introduced in this study, with 88.66% for the decision template fusion (DTF) technique and a consistent enhancement in comparison to all feature sets in terms of accuracy and 86.22% for the NCA feature selection method by drastically downsizing the feature space from 86 elements to only 6 elements. The achieved results showed great potential for identifying a certain pathology from other pathologies that may have similar effects on the cry patterns as well as proving the success of the proposed framework.


Assuntos
Choro , Recém-Nascido , Humanos , Psicoacústica
5.
Nat Commun ; 15(1): 1482, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38369535

RESUMO

The phenomenon of musical consonance is an essential feature in diverse musical styles. The traditional belief, supported by centuries of Western music theory and psychological studies, is that consonance derives from simple (harmonic) frequency ratios between tones and is insensitive to timbre. Here we show through five large-scale behavioral studies, comprising 235,440 human judgments from US and South Korean populations, that harmonic consonance preferences can be reshaped by timbral manipulations, even as far as to induce preferences for inharmonic intervals. We show how such effects may suggest perceptual origins for diverse scale systems ranging from the gamelan's slendro scale to the tuning of Western mean-tone and equal-tempered scales. Through computational modeling we show that these timbral manipulations dissociate competing psychoacoustic mechanisms underlying consonance, and we derive an updated computational model combining liking of harmonicity, disliking of fast beats (roughness), and liking of slow beats. Altogether, this work showcases how large-scale behavioral experiments can inform classical questions in auditory perception.


Assuntos
Música , Humanos , Psicoacústica , Música/psicologia , Percepção Auditiva , Emoções , Julgamento , Estimulação Acústica
6.
J Acoust Soc Am ; 155(1): 68-77, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-38174963

RESUMO

Hearing-impaired (HI) listeners have been shown to exhibit increased fusion of dichotic vowels, even with different fundamental frequency (F0), leading to binaural spectral averaging and interference. To determine if similar fusion and averaging occurs for consonants, four natural and synthesized stop consonants (/pa/, /ba/, /ka/, /ga/) at three F0s of 74, 106, and 185 Hz were presented dichotically-with ΔF0 varied-to normal-hearing (NH) and HI listeners. Listeners identified the one or two consonants perceived, and response options included /ta/ and /da/ as fused percepts. As ΔF0 increased, both groups showed decreases in fusion and increases in percent correct identification of both consonants, with HI listeners displaying similar fusion but poorer identification. Both groups exhibited spectral averaging (psychoacoustic fusion) of place of articulation but phonetic feature fusion for differences in voicing. With synthetic consonants, NH subjects showed increased fusion and decreased identification. Most HI listeners were unable to discriminate the synthetic consonants. The findings suggest smaller differences between groups in consonant fusion than vowel fusion, possibly due to the presence of more cues for segregation in natural speech or reduced reliance on spectral cues for consonant perception. The inability of HI listeners to discriminate synthetic consonants suggests a reliance on cues other than formant transitions for consonant discrimination.


Assuntos
Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Psicoacústica , Fonética , Audição
7.
Int J Audiol ; 63(2): 127-135, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36633444

RESUMO

OBJECTIVE: The aim of this study was to investigate whether consumer-grade mobile audio equipment can be reliably used as a platform for the notched-noise test, including when the test is conducted outside the laboratory. DESIGN: Two studies were conducted: Study 1 was a notched-noise masking experiment with three different setups: in a psychoacoustic test booth with a standard laboratory PC; in a psychoacoustic test booth with a mobile device; and in a quiet office room with a mobile device. Study 2 employed the same task as Study 1, but compared circumaural headphones to insert earphones. STUDY SAMPLE: Nine and ten young, normal-hearing participants completed studies 1 and 2, respectively. RESULTS: The test-retest accuracy of the notched-noise test on the mobile implementation did not differ from that for the laboratory setup. A possible effect of the earphone design was identified in Study 1, which was corroborated by Study 2, where test-retest variability was smallest when comparing results from experiments conducted using identical acoustic transducers. CONCLUSIONS: Results and test-retest repeatability comparable to standard laboratory settings for the notched-noise test can be obtained with mobile equipment outside the laboratory.


Assuntos
Acústica , Ruído , Humanos , Ruído/efeitos adversos , Psicoacústica , Computadores de Mão , Transdutores
8.
Augment Altern Commun ; 40(1): 57-67, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37811949

RESUMO

Children with complex communication needs often have multiple disabilities including visual impairments that impact their ability to interact with aided augmentative and alternative communication (AAC) systems. Just as the field benefited from a consideration of visual cognitive neuroscience in construction of visual displays, an exploration of psychoacoustics can potentially assist in maximizing the possibilities within AAC systems when the visual channel is either (a) not the primary sensory mode, or (b) is one that can be augmented to ultimately benefit AAC outcomes. The purpose of this paper is to highlight background information about psychoacoustics and present possible future directions for the design of aided AAC system technologies for children with visual impairments who rely on auditory information to learn and utilize AAC.


Assuntos
Auxiliares de Comunicação para Pessoas com Deficiência , Transtornos da Comunicação , Criança , Humanos , Psicoacústica , Transtornos da Comunicação/psicologia , Comunicação , Transtornos da Visão
9.
PLoS One ; 18(12): e0294645, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38051728

RESUMO

There is debate whether the foundations of consonance and dissonance are rooted in culture or in psychoacoustics. In order to disentangle the contribution of culture and psychoacoustics, we considered automatic responses to the perfect fifth and the major second (flattened by 25 cents) intervals alongside conscious evaluations of the same intervals across two cultures and two levels of musical expertise. Four groups of participants completed the tasks: expert performers of Lithuanian Sutartines, English speaking musicians in Western diatonic genres, Lithuanian non-musicians and English-speaking non-musicians. Sutartines singers were chosen as this style of singing is an example of 'beat diaphony' where intervals of parts form predominantly rough sonorities and audible beats. There was no difference in automatic responses to intervals, suggesting that an aversion to acoustically rough intervals is not governed by cultural familiarity but may have a physical basis in how the human auditory system works. However, conscious evaluations resulted in group differences with Sutartines singers rating both the flattened major as more positive than did other groups. The results are discussed in the context of recent developments in consonance and dissonance research.


Assuntos
Música , Canto , Humanos , Psicoacústica , Reconhecimento Psicológico , Estado de Consciência , Estimulação Acústica/métodos , Percepção Auditiva/fisiologia
10.
J Acoust Soc Am ; 154(4): 1963-1976, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782118

RESUMO

Appropriate sound quality models for noise-induced discomfort are necessary for a better acoustic comfort design in the aircraft cabin. This study investigates the acoustic discomfort in two large passenger aeroplanes (i.e., planes A and B). We recorded the noise at 21 positions in each aircraft cabin and selected 42 stimuli ranging from 72 to 81 dB(A) during the cruising flights. Twenty-four participants rated the noise discomfort by the absolute magnitude estimation method. The discomfort values in the middle section of the aircraft cabin are 10% points higher than in the front or rear section. The discomfort magnitude was dominated by loudness and influenced by roughness and sharpness. A multiple linear (MA) discomfort model was established, accounting for the relationship between the discomfort and sound quality metrics (i.e., loudness, sharpness, and roughness). The MA model estimated noise discomfort better than the Zwicker and other (i.e., More and Di) psychoacoustic annoyance (PA) models. We modified the coefficients of independent variables in the formulations of Zwicker, Di, and More PA models, respectively, according to the present experimental results. The correlation coefficients between the estimated and measured values of the modified models were at least 20% points higher than the original ones.


Assuntos
Ruído , Som , Humanos , Psicoacústica , Modelos Lineares , Aeronaves
11.
J Acoust Soc Am ; 154(3): 1770-1786, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37721403

RESUMO

Both dynamic variation of interaural time difference (ITD) and static spectral cues provide information for front-back discrimination and vertical localization. However, the contributions of the two cues are still unclear. The static spectral cue has conventionally been regarded as the dominant one. In the present work, psychoacoustic experiments were conducted to examine the contribution of dynamic ITD and static spectral cues to vertical localization in the median plane. By modifying the head-related transfer functions used in a dynamic virtual auditory display, binaural signals with conflicting dynamic ITD and spectral cues that were either static or dynamically modified according to instantaneous head position were created. The results indicated that the dynamic ITD and static spectral cues contribute to vertical localization at low and high frequencies, respectively. For full a bandwidth stimulus, conflicting dynamic ITD and static spectral cues usually result in two separated virtual sources at different elevations corresponding to the spatial information conveyed by the low- and high-frequency bands, respectively. In most cases, no fused localization occurs in the high-level cognition system. Therefore, dynamic ITD and static spectral cues contribute to vertical localization at different frequency ranges, and neither of them dominates vertical localization in the case of wideband stimuli.


Assuntos
Sinais (Psicologia) , Localização de Som , Cognição , Psicoacústica
12.
Eur J Neurosci ; 58(7): 3686-3704, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37752605

RESUMO

Human listeners prefer octave intervals slightly above the exact 2:1 frequency ratio. To study the neural underpinnings of this subjective preference, called the octave enlargement phenomenon, we compared neural responses between exact, slightly enlarged, oversized, and compressed octaves (or their multiples). The first experiment (n = 20) focused on the N1 and P2 event-related potentials (ERPs) elicited in EEG 50-250 ms after the second tone onset during passive listening of one-octave intervals. In the second experiment (n = 20) applying four-octave intervals, musician participants actively rated the different octave types as 'low', 'good' and 'high'. The preferred slightly enlarged octave was individually determined prior to the second experiment. In both experiments, N1-P2 peak-to-peak amplitudes attenuated for the exact and slightly enlarged octave intervals compared with compressed and oversized intervals, suggesting overlapping neural representations of tones an octave (or its multiples) apart. While there were no differences between the N1-P2 amplitudes to the exact and preferred enlarged octaves, ERP amplitudes differed after 500 ms from onset of the second tone of the pair. In the multivariate pattern analysis (MVPA) of the second experiment, the different octave types were distinguishable (spatial classification across electroencephalography [EEG] channels) 200 ms after second tone onset. Temporal classification within channels suggested two separate discrimination processes peaking around 300 and 700 ms. These findings appear to be related to active listening, as no multivariate results were found in the first, passive listening experiment. The present results suggest that the subjectively preferred octave size is resolved at the late stages of auditory processing.


Assuntos
Potenciais Evocados , Música , Humanos , Psicoacústica , Eletroencefalografia , Percepção Auditiva/fisiologia , Potenciais Evocados Auditivos/fisiologia , Estimulação Acústica
13.
J Acoust Soc Am ; 154(2): 751-762, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37556566

RESUMO

Web-based testing is an appealing option for expanding psychoacoustics research outside laboratory environments due to its simple logistics. For example, research participants partake in listening tasks using their own computer and audio hardware and can participate in a comfortable environment of their choice at their own pace. However, it is unknown how deviations from conventional in-lab testing affect data quality, particularly in binaural hearing tasks that traditionally require highly precise audio presentation. Here, we used an online platform to replicate two published in-lab experiments: lateralization to interaural time and level differences (ITD and ILD, experiment I) and dichotic and contralateral unmasking of speech (experiment II) in normal-hearing (NH) young adults. Lateralization data collected online were strikingly similar to in-lab results. Likewise, the amount of unmasking measured online and in-lab differed by less than 1 dB, although online participants demonstrated higher speech reception thresholds overall than those tested in-lab by up to ∼7 dB. Results from online participants who completed a hearing screening versus those who self-reported NH did not differ significantly. We conclude that web-based psychoacoustics testing is a viable option for assessing binaural hearing abilities among young NH adults and discuss important considerations for online study design.


Assuntos
Percepção da Fala , Adulto Jovem , Humanos , Psicoacústica , Audição , Percepção Auditiva , Internet
14.
Atten Percept Psychophys ; 85(8): 2797-2810, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37349625

RESUMO

A major barrier to the clinical application of psychophysical testing of central auditory processes is the time required to obtain precise estimates of different listening abilities. In this study, we validate a novel adaptive scan (AS) method of threshold estimation that is designed to adapt on a range of values around threshold rather than on a single threshold value. This method has the advantage of providing the listener with greater familiarity with the stimulus characteristics near threshold while maintaining precise measurement and increasing time-efficiency. Additionally, we explore the time-efficiency of AS through comparison with two more conventional adaptive algorithms and the method of constant stimuli in two common psychophysical tasks: the detection of a gap in noise and the detection of a tone in noise. Seventy undergraduates without hearing complaints were tested using all four methods. The AS method provided similar threshold estimates with similar precision to those from the other adaptive methods and, thus, it is a valid adaptive method of psychophysical testing. We also provide an analysis of the AS method based on precision metrics to propose a shortened version of the algorithm that maximizes the time/precision tradeoff and can achieve similar thresholds to the adaptive methods tested in the validation. This work lays the foundation for using AS across a wide variety of psychophysical assessments and experimental situations where different levels of precision and/or time-efficiency may be required.


Assuntos
Algoritmos , Ruído , Humanos , Limiar Auditivo , Psicoacústica , Fatores de Tempo
15.
JASA Express Lett ; 3(4)2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-37096893

RESUMO

A listener's judgement on the perceptual distance between two sounds usually draws on their psychoacoustic difference, but can also be subject to L1-specific perception. This study investigates the interplay between these two aspects when evaluating the perceptual distance of sound pairs. Mandarin and English listeners rated the perceptual distance of consonant-vowel pairs corresponding to sequences legal or illegal in their L1s. The results suggested that a similarity rating task can provide a finer assessment of distinctiveness between sound pairs as compared to a discrimination task. The results also showed how psychoacoustic perception may interact with L1-specific perception in this process.


Assuntos
Percepção da Fala , Psicoacústica , Fonética , Som
16.
J Acoust Soc Am ; 153(4): 2482, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-37092950

RESUMO

Physiological and psychoacoustic studies of the medial olivocochlear reflex (MOCR) in humans have often relied on long duration elicitors (>100 ms). This is largely due to previous research using otoacoustic emissions (OAEs) that found multiple MOCR time constants, including time constants in the 100s of milliseconds, when elicited by broadband noise. However, the effect of the duration of a broadband noise elicitor on similar psychoacoustic tasks is currently unknown. The current study measured the effects of ipsilateral broadband noise elicitor duration on psychoacoustic gain reduction estimated from a forward-masking paradigm. Analysis showed that both masker type and elicitor duration were significant main effects, but no interaction was found. Gain reduction time constants were ∼46 ms for the masker present condition and ∼78 ms for the masker absent condition (ranging from ∼29 to 172 ms), both similar to the fast time constants reported in the OAE literature (70-100 ms). Maximum gain reduction was seen for elicitor durations of ∼200 ms. This is longer than the 50-ms duration which was found to produce maximum gain reduction with a tonal on-frequency elicitor. Future studies of gain reduction may use 150-200 ms broadband elicitors to maximally or near-maximally stimulate the MOCR.


Assuntos
Cóclea , Emissões Otoacústicas Espontâneas , Humanos , Psicoacústica , Cóclea/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Reflexo/fisiologia , Fatores de Tempo , Estimulação Acústica , Mascaramento Perceptivo/fisiologia
17.
Atten Percept Psychophys ; 85(8): 2718-2730, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36949259

RESUMO

Auditory localization plays an essential role in various tasks, including spatial orientation, locomotion, attention and memory. Optimization of experimental routine is important for preliminary assessment of the subject's sound localization ability. In the present study, a new quick technique for estimating the relative minimum audible distance (RMAD) using sound images is introduced. Twenty adults with normal hearing took part in six RMAD measurements in free field. The reference RMAD values were obtained using a method of constant stimuli by physically positioning a real sound source. The same method was used with stationary sound images created by superposition of signals emitted by two loudspeakers. To optimize the measurements, the RMADs were determined for the sound images using two adaptive psychoacoustic procedures known as one-down, one-up and two-down, one-up staircases. The group-average RMADs obtained by the method of constant stimuli for both types of stimuli and by two adaptive procedures were similar, 7% (SD = 2%). The effect of whether subjects were sighted or blindfolded was not significant for measurements of RMAD to sound images. The average measurement times were 373 s (SD = 20 s) for the method of constant stimuli, 85 s (SD = 9 s) for the one-down, one-up, and 124 s (SD = 14 s) for the two-down, one-up procedure. The results are consistent with the previous studies and confirm the validity of the measurements of RMAD using adaptive procedures with stationary sound images as a quick method.


Assuntos
Localização de Som , Adulto , Humanos , Som , Psicoacústica , Testes Auditivos , Percepção Espacial
18.
J Psycholinguist Res ; 52(4): 1141-1170, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36929042

RESUMO

This study sought to determine whether rap expertise is associated with enhanced knowledge of psychoacoustic similarity. Using a stimulus composed of pseudo-word assonantal half-rhyme triplets (e.g., freet/speet//yeek), expert improvisational rap lyricists were compared to laypersons (non-lyricists) in their judgments of half-rhyme acceptability. According to both a perception-based and a linguistic feature-based measure of psychoacoustic similarity, lyricists were distinct from non-lyricists in the rates at which they found half-rhymes acceptable, and in how group responses were correlated with the similarity measures. Data indicate that, compared to non-lyricists, lyricists' half-rhyme acceptance rates are more highly correlated with linguistic features that have more robust perceptual cues. Evidence suggests that lyricists and non-lyricists employ different strategies for determining the acceptability of half-rhymes, and that lyricists might be more sensitive or attuned to similar aspects of speech sounds.


Assuntos
Julgamento , Percepção da Fala , Humanos , Psicoacústica , Fonética , Sinais (Psicologia)
19.
Artigo em Inglês | MEDLINE | ID: mdl-36767321

RESUMO

Aeroacoustic noise in multiple rotor drones has been increasingly recognized as a crucial issue, while noise reduction is normally associated with a trade-off between aerodynamic performance and sound suppression as well as sound quality improvement. Here, we propose an integrated methodology to evaluate both aeroacoustics and psychoacoustics of a single propeller. For a loop-type propeller, an experimental investigation was conducted in association with its aerodynamic and acoustic characteristics via a hover stand test in an anechoic chamber; the psychoacoustic performance was then examined with psychoacoustic annoyance models to evaluate five psychoacoustic metrics comprising loudness, fluctuation strength, roughness, sharpness, and tonality. A comparison of the figure of merit (FM), the overall sound pressure level (OASPL) and psychoacoustic metrics was undertaken among a two-blade propeller, a four-blade propeller, the loop-type propeller, a wide chord loop-type propeller, and a DJI Phantom III propeller, indicating that the loop-type propeller enables a remarkable reduction in OASPL and a noticeable improvement in sound quality while achieving comparable aerodynamic performance. Furthermore, the psychoacoustic analysis demonstrates that the loop-type propeller can improve the psychological response to various noises in terms of the higher-level broadband and lower-level tonal noise components. It is thus verified that the integrated evaluation methodology of aeroacoustics and psychoacoustics can be a useful tool in the design of low-noise propellers in association with multirotor drones.


Assuntos
Ruído , Som , Psicoacústica , Acústica , Benchmarking
20.
J Speech Lang Hear Res ; 66(1): 16-29, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36516473

RESUMO

PURPOSE: Acoustic and perceptual quantification of vocal strain has been a vexing problem for years. To increase measurement rigor, a suitable single-variable matching stimulus for strain was developed and validated, based on the matching stimulus used previously for breathy and rough voice qualities. METHOD: A set of 21 comparison stimuli for a single-variable matching task (SVMT) was synthesized based on a speech-shaped sawtooth waveform mixed with speech-shaped noise. Variable bandpass filter gain in mid-to-high frequencies achieved a wide range of computed sharpness (in constant sharpness steps) and served as the independent variable for the SVMT. Ten natural /ɑ/ stimuli with a wide range of the primary voice quality of strain and a minimum of breathiness or roughness were selected and assessed using the SVMT. Natural voice samples and synthetic comparison stimuli were also assessed using a perceptual magnitude estimation (ME) task. RESULTS: ME data validated the correspondence of the set of comparison stimuli to varying perceived strain. Perceived strain magnitudes of the comparison stimuli increased significantly and linearly with computed sharpness (r 2 = .99). A linear regression revealed that strain matching values were significantly predicted by computed sharpness (r 2 = .96) and perceived strain magnitudes (r 2 = .95) of the natural voice stimuli. CONCLUSION: The perception of vocal strain is strongly associated with computed sharpness and is captured accurately and precisely using an SVMT, in which the independent variable is the bandpass filter gain (in steps of equal sharpness) applied to the comparison stimuli.


Assuntos
Percepção da Fala , Qualidade da Voz , Humanos , Psicoacústica , Acústica da Fala , Acústica , Medida da Produção da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...